Application | Indoor, Outdoor, 16-hr operation daily | |
Rise H(m) | <=6 | <=10 |
Angle of inclination (°) | 35 | 30 |
Step width (mm) | 600/800/1000 | |
Horizontal steps | 2/2 | 2/2 3/3* |
Main power | 380V/50Hz/3P | |
Balustrade | Tempered glass (10mm) | |
Handrail bracket | Stainless steel | |
Handrail | Black | |
Balustrade height | 900 | |
Inner & decking | Hairline stainless steel | |
Skirting | Hairline stainless steel | |
Step | Stainless steel | |
Landing plate | Stainless steel (anti-sliding) | |
Illumination | Lighting under upper & lower landing steps | |
Indicator | Failure code indicator on control cabinet | |
Operation | Emergency stop button Inspection operation |
Application | Indoor, Outdoor, 16-hr operation daily |
Rise H(m) | <=16 |
Inclination (°) | 30 |
Step width (mm) | 600/800/1000 |
Horizontal steps | 3/3 |
Speed | 0.5 |
Main power | 380V/50Hz/3P |
Balustrade | Tempered glass (10mm) |
Handrail bracket | Stainless steel |
Handrail | Black |
Balustrade height | 900 |
Inner & outer decking | Hairline stainless steel |
Skirting | Hairline stainless steel |
Step | Stainless steel |
Landing plate | Stainless steel (anti-sliding) |
Illumination | Lighting under upper & lower landing steps |
Indicator | Failure code indicator on control cabinet |
Operation | Emergency stop button Inspection operation |
Application | Indoor, Outdoor, 20-hr operation daily | |
Rise H(m) | <=6 | <=27 |
Angle of inclination (°) | 35 | 30 |
Step width (mm) | 100/800/600 | |
Horizontal steps | 2/2 | 2/2 3/3* |
Speed | 0.5 | |
Main power | 380V/50Hz/3P | |
Balustrade | Stainless steel inclined balustrade; Tempered glass (10mm) | |
Handrail bracket | Stainless steel | |
Handrail | Black | |
Balustrade height | 1000 | |
Inner & outer decking | Hairline stainless steel | |
Skirting | Hairline stainless steel | |
Step | Stainless steel | |
Landing plate | Stainless steel (anti-sliding) | |
Illumination | Lighting under upper & lower landing steps | |
Indicator | Failure code indicator on control cabinet | |
Operation | Emergency stop button Inspection operation |
Application | Indoor, 16-hr operation daily |
Horizontal span (m) | <=150 |
Angle of inclination (°) | 0-6 |
Pallet width (mm) | 800/1000 |
Speed | 0.5 |
Main power | 380V/50Hz/3P |
Balustrade | Tempered glass (10mm) |
Handrail bracket | Stainless steel |
Handrail | Black |
Balustrade height | 900 |
Inner & outer decking | Hairline stainless steel |
Skirting | Hairline stainless steel |
Pallet | Stainless steel |
Landing plate | Stainless steel (anti-sliding) |
Illumination | Lighting under upper & lower landing pallets |
Indicator | Failure code indicator on control cabinet |
Operation | Emergency stop button Inspection operation |
Application | Indoor, 16-hr operation daily |
Horizontal span (m) | <=50 |
Angle of inclination (°) | 10/11/12 |
Pallet width (mm) | 800/1000 |
Upper landing horizontal distance | 400 |
Speed | 0.5 |
Main power | 380V/50Hz/3P |
Balustrade | Tempered glass (10mm) |
Handrail bracket | Stainless steel |
Handrail | Black |
Balustrade height | 900 |
Inner & outer decking | Hairline stainless steel |
Skirting | Hairline stainless steel |
Pallet | Stainless steel |
Landing plate | Stainless steel (anti-sliding) |
Illumination | Lighting under upper & lower landing pallets |
Indicator | Failure code indicator on control cabinet |
Operation | Emergency stop button Inspection operation |